Forum

Todd Hensley
Todd Hensley
Joined: Oct 18, 2020
Last seen: Jan 1, 2021
Topics: 2 / Replies: 7
Reply
RE: Firewall Forward P Lead Replacement

@patricbarry Thanks Pat! This is exactly what I wanted an opinion on! I just couldn't make sense of the shielding for grounding's sake. It just didn'...

4 years ago
Reply
RE: Firewall Forward P Lead Replacement

@patricbarry Thanks. I understand the requirements. I'm just interested to know what other A&P's have done. I've worked under an A&P for th...

4 years ago
Topic
Reply
RE: PA30 Electrical Failure

Sorry. Per the Service Manual, it's actually called the "Paralleling Relay". It's the center one in the cluster of three located in the nose.

4 years ago
Reply
RE: PA30 Electrical Failure

My issue turned out to be a stuck contactor in the switching regulator. A little TLC, and it's working properly for now. Todd

4 years ago
Reply
RE: PA30 Electrical Failure

@williamh I'll be looking in to those! I've always had a little concern about cramming all those sparking solenoids and relays under the hood with the...

4 years ago
Reply
RE: PA30 Electrical Failure

@williamh Thanks! This project did set for a long time initially. I found a stuck contact in the switching regulator. Cleaned it up slightly. When I...

4 years ago
Reply
RE: PA30 Electrical Failure

@patricbarryThanks for the quick reply! I do have 30 years or so electrical and mechanical experience and have been working with an A&P for the l...

4 years ago
Topic
Replies: 13
Views: 1291
Comanche Tech Talk
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.